±t¥dÅã·LÃè¨t²Î
¹p®g±½´y¦@³mµJÅã·LÃè
¥b¾ÉÅé¤Î¤u·~¥ÎÅã·LÃè
Åã·L¼Æ¦ì¼v¹³¨t²Î
²Ó­M°ò¦]¼v¹³¤ÀªR¨t²Î
¨ä¥¦¥ú¹q·L¾÷¹q¨t²Î
¨ä¥¦¥ÍÂå¬ã¨s»ö¾¹
ºû­×»P§Þ³N¤ä´©ªA°È
Ápµ¸»P¯d¨¥
¡@
¡@
¡@ ¤F¸Ñ Leica ¦b Super-Resolution ªº¸Ñ¨M¤è®× »P »â¾ÉÁÍ¶Õ ..
¡@ ¡@
¡@
¡@
¦h¤@ÂI¤F¸Ñ Leica TCS SP5 ªº¨ô¶V, »P¨ä¥L²£«~ªº®t²§©Ê¦b­þ¸Ì ?

The Leica TCS SMD FLIM system is part of the Leica TCS SMD Series.

It is a dedicated system for FLIM measurements. These measurements reveal information about the direct neighborhood of molecules on the nanometer scale.

Local conditions can determine folding states that influence the reactivity of molecules. FLIM is also used for binding studies (FLIM-FRET) and to identify natural metabolites under physiological conditions. The SMD FLIM wizard optimizes FLIM measurement conditions and allows the setup of FLIM time series or FLIM stacks

The Leica TCS SMD Series integrates hardware and software from PicoQuant with the high-end confocal system Leica TCS SP5 II. Researchers can now control a complete SMD experiment via one interface, the LAS AF software from Leica Microsystems. The coordination of different hardware and software components for one SMD experiment is now a thing of the past.

Field upgrades of Leica TCS SP5 and SP5 II confocal systems to any of the Leica TCS SMD systems, FCS, FLIM and FLCS, are possible

®É¶¡¸ÑªR¿Ã¥ú§Þ³N (Time-demand Fluorescence Technology)

¿Ã¥ú§Þ³NÀ³¥Î©ó¬ã¨s»â°ì¤¤¤w¸g¤Q¤À¦¨¼ô¡A¤H­Ì¥i¥HÂǥѲ³æªº¿Ã¥úªiªøÅܤưµ¬°°Ï¤À¡A¨Ò¦p¥H¤£¦Pªº¿Ã¥ú¬V¾¯°w¹ï²Ó­M¤¤¤£¦Pªº³¡¦ì¼Ð­q¡A¨Ã¥H­Ó§Oªiªøªº¿Eµo¥ú¤Î¿Ã¥ú°T¸¹ªi¬qÂ^¨ú¡A«K¥i¥HÀò±o²Ó­M¤£¦P°Ï°ìªº¼v¹³¡ADAPI¬V²Ó­M®Ö¡BFITC¬V²Ó­M°©¬[¡BTRITC¬V²É½uÅéµ¥¡AÂÇ¥ÑÅ|¹Ï±N¾ã¤ù¼v¹³§e²{¥X¨Ó¡C(¹Ï¬°¦@³mµJ¿Ã¥ú¼v¹³)¡C©Î¬O¥Ñ¿Ã¥ú¥ú±jªº§ïÅܨÓÀò±o¸ê°T¡A¨Ò¦p¦b¬Y¨Ç°Ï°ì¤¤¿Ã¥úªºªí²{¶q¦h¹è§PÂ_²Ó­MÅܤơA¥H¤ÎIntensity base FRET (Förster Resonance Energy Transfer)¡A¥iÂÇ¥ÑDonor-Accepter¶¡¦@®¶ªº¯à¶qÂà´«Àò±o¿Ã¥ú±j®zªº§ïÅÜ¡AÀò±o³J¥Õ½è¶¡¥æ¤¬§@¥Î¥H¤Î¥Íª«¸ê°T¡C

¡@

¡@
¡@ ¡@

¦P¤@®É¶¡¡A¥ú¾Ç§Þ³N¤]¤£Â_ºt¶i¡A¦@³mµJÅã·L§Þ³N(Confocal Microscope)§Þ³N¥Ñ¤£¥i¯àÅܦ¨¥i¯à¡A§ó¶i¤@¨B¦¨¬°¤@¶µ¤è«Kªº¨Ï¥Î¤u¨ã¡A¥t¥~¹p®g¥úªºµo®i¡B¥ú¹q­¿¼WºÞ§Þ³N(Photomultiplier tube, PMT)§Þ³N¦¨¼ô¡BAOBS (Acousto-Optical Beam Splitter)µ¥¦U¶µ§Þ³N³£¦¨¬°¿Ã¥ú¼v¹³¤Wªº±o¤O§U¤â¡C

¦ý¬O¿Ã¥úªiªø¥H¤Î¥ú±jªº§ïÅܬO³Ì®e©ö³Q¤H·Pı®t²§¡A¤]¬O³Ìª½±µªºÆ[´ú¤è¦¡¡CµM¦Ó·í¿Ã¥ú¬V¾¯ªºªiªø¤Ó¹L¬Ûªñ©Î¬O·L®zªº¿Ã¥ú°T¸¹¡A´NµLªk¨Ï¥Î¶Ç²ÎªºÅã·L§Þ³N°µ¶q´ú¡A¦]¦¹¥Ñ¥H¤Uªº§Þ³Nµo®i¡C

¥Ø«e, ¬ã¨s¬É°w¹ï¿Ã¥ú¹Ø©R´ú©wªº¤èªk, ¦³¤TºØ :

1. §Y®É¬ÛÃö³æ¤À¤l­p¼Æªk ( Time-correlated Single Photon Counting, TCSPC ).

2. ÀW°ìªk - ¬Û½Õ¨îªk. Frequency-domain ( phase modulation ) method.

3. ÀW°{§Þ³N ( Strobe techniques )

¡@


FLIM §Þ³N¤¶²Ð»PÀ³¥Î

Fluorescence Lifetime Image Microscopy (¿Ã¥ú¥Í©R¶g´Á¼v¹³Åã·L§Þ³N¡B¥H¤U²ºÙFLIM)¬O­pºâ¿Ã¥ú¤À¨ü¿Eµo«á¡A¹q¤lªº°±¯d¦b¿EµoºAªº®É¶¡¡A²Ö¿nÅ|¥[«áÁͪñ(Fitting)ªºµ²ªG¡C·í­ì¥»¦b°òºAªº¤À¤l¦b±µ¨ü¨ì¿Eµo¥ú¥ú¤lÅD¾E¨ì¿EµoºAªº®É­Ô¡A¤j¬ù·|°±¯d1¨ì100 ns (10-9-10-7¬í)¡A¨Ì·Ó¤£¦Pªº¿Ã¥ú¤À¤l¡B¤£¦Pªº¾÷¨î¡A·|³y¦¨¯dº¢®É¶¡ªº¤£¦P¡A¥i¥H¥Î¨Ó§PÂ_¥úÃЬ۪ñ¦ýlifetime¤£¦Pªº¿Ã¥ú¬V¾¯¡C

FLIM¶q´ú»Ý­n¥H¤U¤T¶µ§Þ³Nªº°t¦X

1.      ¯ß½Ä¹p®g(Pulse Laser)

FLIM­n¶q´úLifetimeªº®É¶¡¡A»Ý­n®É¶¡ªº¹sÂI¥H¤Î®É¶¡¶b¨Ó­pºâLifeitme¡A¦]¦¹¯ß½Ä¹p®gÅܬO³Ì¥D­nªº¿Eµo¥ú·½¡A¦P®É¤]¬O®É¶¡ªøµuªº©w¸q¡A¥H80MHzªº¯ß½Ä¹p®g¬°¨Ò¡A¦b¤@¬íÄÁ·|¦³¤K¤d¸Uµo¯ß½Ä¡A©Ò¥H¯ß½Ä¶¡ªº®É¶¡¶¡¹j¤j¬ù¬°12.5 ns¡A§Q¥Î¯ß½Ä¹p®gÀò±o®É¶¡¶¡¶Z¡A¦P®É¯ß½Ä¹p®g°µ¬°¿Ã¥úªº¿Eµo¡A«K¥i¥H²Ö¿n¦b¤£¦P®É¶¡ÂI³Q°»´ú¨ìªº¥ú¤l°T¸¹¡C¦]¦¹¯ß½Ä¹p´úªº¯ß½Ä¼e«×(Pulse Duration)¶Vµu¶V¦n¡A¥i¥H´î¤ÖAfter Pulseªº¿Ã¥ú°T¸¹³QDetector¦¬¨ì¡A¦Ó¼vÅTLifetimeªº­pºâ¡C

2.      FLIM Detector

¥Ñ©óFLIM§Þ³Nªº¿Ã¥ú¬Û·í©ó³æ¥ú¤lªº²Ö¿n¡A¦]¦¹FLIM§Þ³N©Ò¨Ï¥Îªº°»´ú¾¹¤j¦h¨Ï¥Î§N«oªºPMT©Î¬OAPD (Avalanche photodiode)¨Ó°µ¬°¿Ã¥ú°T¸¹ªº±µ¨ü¡C§N«o§Þ³N¥i¥H½T«OS/N Ratio¡A¼W¥[FLIM¶q´úªº·Ç½T©Ê¡C¨Ã¥B»Ý­n±N°»´ú¾¹»PFLIMªº§Þ³N¶q´ú¤¸¥ó°µ¾A·íªº³sµ²¡A¤~¥i¥HÀò±o·Ç½TªºLifetime°T¸¹¡C

3.      TCSPC

TCSPC (Time Correlated Single Photon Counting)¬OFLIM§Þ³Nªº®Ö¤ß¡A¯ß½Ä¹p®gªº¯ß½Ä¿é¤J»P¥ú¤l°T¸¹¨ì¹F°»´ú¾¹®É¡ATCSPC¶q´ú¨Ã²Ö¿n¤§«á«K¥i¥HÀò±o¿Ã¥ú¥ú±jÀH®É¶¡ªºDecay¦±½u¡C¥H¦ÛµM¹ï¼Æªº¤èµ{¦¡¹GªñÀò±o¿Ã¥ú¥Í©R¡C

¨ä¤¤I (t)¬O¥ú¤l¼Æ®É¶¡ªº¨ç¼Æ¡AI0¬O­ì©l¥ú±j¡A£n¬O¿Ã¥úªºLifetime¡At¬O®É¶¡¡C¥Ñ©ó¥ú±jªº°I´î¬O¥H¦ÛµM¹ï¼Æªº¦æ¨Æ¡A¦]¦¹³q±`¥ú¤l¼Æ·|Âk¤@¤Æ¡A¨Ã¥B¬O¥H¯Å¼Æªº¤è¦¡§e²{¡C

FLIM¯S§OÀ³¥Î©ó¶q´ú¥úÃеLªk¤ÀªRªº¿Ã¥ú¤À¤l¡AÁ|¨Ò¨Ó»¡¡A¦pªG¤µ¤Ñ¦³¨â­Ó¿Ã¥ú¤À¤l¦P®É¬V¦b¤@­Ó°Ï°ì¤¤¡A¦ý¬O¿Eµo»P©ñ®g¥úÃФQ¤À¬Ûªñ¡A¥i¥H§Q¥ÎFLIMªº§Þ³N°µ¬°°Ï§O¡C¥t¥~¿Ã¥ú¬V¾¯¹ï©ó·L¤pªºÀô¹ÒÅܤƦ³«Ü¤jªº¤ÏÀ³¡A¦bpH¡BÂ÷¤l¿@«×¡B·Å«×¤Î·¥©Êµ¥±ø¥óªº§ïÅܤU¡A·|¥X²{¿Ã¥úLifetimeªºÅܤơA§ó¥[®e©öÆ[´ú¡C

¦b Leica TCS SMD FLIM ¨t²Îªº³]­p¤U¡A©Ò¦³ªº¤º«Ø cooled PMT detector §¡¬°¤ô§N¦¡³]­p¡A¯à¦³®Ä´£°ªS/N¤ñ¨Ò¡C¥i¥H¥Ñ¨Ï¥ÎªÌºÝµøª¬ªp¤Î»Ý¨D¡A¥i¿ï¾Ü405 nm¡B470 nm ©Î¬O 640 nm ªº³æ¤À¤l¯ß½Ä¹p®g¡A©Î¬O¥i½ÕÅܦ¡¦h¥ú¤l IR ¹p®g (680-1040 nm)¡AºÝ¬Ý¨Ï¥ÎªÌªº»Ý¨D¡C

Leicaªº§@·~¨t²Î©ÓŧµÛ¥H©¹ªººD¨Ò¡A¦¨¥\±N©Ò¦³ªºFLIM³nÅé¾ã¦X¦¨¬°¦b³æ¤@¨Ï¥Î¤¶­±¡AÅý¨Ï¥Î³oµL¶·¯h©ó§ó´«¾Þ±±¹q¸£¡A¨Ã§Q¥Î Leica ªº³nÅé¡AÅý¨Ï¥ÎªÌ¥i¥H»´ÃPªº¨Ï¥Î¤º«Ø®M¥ó¨Ó¶q´ú FLIM¡A½T«O¨Ï¥ÎªÌ¹êÅ祿½T¤Î§¹¾ã¡C

¡@

¡@
¡@

Leica TCS SP5 II Scan Head ¹Ï¥Ü

Flexibility to meet your needs  ( D-FLIM, MP-FLIM )
Leica TCS SMD FLIM ¥i¥HÅý¨Ï¥ÎªÌ¦b¹êÅç³Wµe¤¤, ¿ï¾Ü±Ä¥Î D-FLIM ©Î  MP-FLIM. µo´§³Ì°ª¨Ï¥Î®Ä¯q.

D-FLIM ±Ä¥Î ¯ß½Ä¦¡  405 nm , 470 nm, 640 nm ¹p®g§@¬°¾÷µo¥ú·½.

MP-FLIM ±Ä¥Î¬õ¥~¥ú­¸¬í¹p®g  ( Pico or Femto second ).

Quick Results and better data reliability
§Y®É§Ö³tªº FLIM ¼v¹³¦¨¹³, ¨¬¥H¦b¹êÅç¹Lµ{¤¤, §Y®É°õ¦æ°ª³tªº¿Ã¥ú¥ú¤l­p¼Æ³t²v.
Explore even complex fluorescence properties
µ²¦X FLIM ¶q´ú¤ÀªRªº¥úÃЦ¡¦@³mµJÅã·L¼v¹³¨t²Î, ¥i¥H±´´ú¤À¤l¶¡ªº¥æ¤¬§@¥Î, ¤À¤l¶¡¶Z, ¤À¤l¶¡ªº©`¦Ì¯ÅÀô¹ÒÅܤƤÏÀ³, ÂÇ¥H±´ª¾½ÆÂøªº¤À¤l°ÊºAÅܤÆ.
Ready for upgrade to FLCS
Leica TCS SMD FLIM ¨t²Î, ¤º¸m PDM (Photo Diode Module) APDs , °ß¤@¥iª½±µ¦b TCS SP5 II ¤W, ¦b FLIM ªº°ò¦, ª½±µ¤É¯Å¨ì  FCS (Fluorescence Correlation Spectroscopy) ¨t²Î, ¦¨¬°¥þ¥@¬É°ß¤@ªº¥þ¥úÃЦ¡¦@³mµJ¼v¹³¨t²Î - TCS SMD FLCS (Fluorescence Lifetime Correlation Spectroscopy) System.

¤@¯ë FLIM ±`¨£ªºÀ³¥Î»â°ì¥]¬A :

Non-stained samples:

  • Metabolic state characterization
  • Cancer research: identification of modified cells
  • Plant physiology: pathogen-host interaction
  • Identification of chitin of lignin structures

Stained samples:

  • Energy transfer (FLIM-FRET for molecule binding)
  • Molecular sub-states (e.g. isomerization, protonation)
  • Local concentration of ions and small ligands
  • Environmental studies (viscosity, refractive index, pH)
  • Dye separation
  • Photophysical dye properties

¡@

Leica TCS SMD FLIM ¬ÛÃö¸ê®Æ¤U¸ü
Leica TCS SMD FLIM ³W®æ»P²Õ°t ¤U¸ü ( PDF )
Leica TCS SMD FLIM ­ì¼t«¬¿ý ¤U¸ü ( PDF )
Leica TCS SP5 II ¨t²Î²Õ°t°Ñ¦Ò ¤U¸ü ( PDF )
¡@
Label-free FLIM application letter À³¥Î§Þ³N»P¤åÄm ¤U¸ü ( PDF )
¬ü¹Å¤½¥q´£¨Ñ LEICA Time-domain FLIM ¥H¤Î homodyne Frequency-domain FLIM ( Lambert LIFA system ). ÀW²v¸ÑªR ¿Ã¥ú¥Í©R¶g´Á ¤§¼v¹³¶q´ú¨t²Î.

Lambert Instruments Fluorescence Attachment - LIFA

  • with modulated LED and modulated ICCD and user-friendly software
    optional: with directly
    modulated diode laser as widefield light source

    ¡@
  • combined to Yokogawa spinning disk for confocal microscopy FLIM images ( µ²¦X°ª³t±½´y¦@³mµJªº FLIM ¨t²Î )

    ¡@
  • combined to laser-TIRF for FLIM images in TIRF mode  ( µ²¦X¿Ã¥ú¥þ¤Ï®gªº FLIM ¨t²Î  )

OR

Build your own Fluorescence Lifetime Imaging Microscopy –FLIM system

  • add the modulated image intensifier II18MD, the key component of the LIFA (Lambert Instruments Fluorescence Attachment)

See our list of test sites where Lambert Instruments fluorescence lifetime imaging products are used and publications list LIFA / II18MD papers for references and information on possible applications.

The picture shows 4 HeLa cells with FRET (Alexa488 and Alexa568) only at the centrosomes (the microtubule organizing centers of the cell): the lifetime of Alexa488 at the centrosomes has decreased to 2,3ns, and the lifetime of Alexa488 outside the centrosomes is 2,7ns. The pseudo colored lifetime is merged with the gray scaled intensity image. Courtesy of Prof. Diaspro, Genua, Italy.

 

Other products in this category:

LIFA-X, for long lifetime phosphorescence imaging
LIFA - combined to Yokogawa spinning disk
LIFA - combined to laser-TIRF
II18MD, modulated image intensifier

¡@

¡@


¡@ ¡@

¡@

¨ä¥L²£«~¸Ô²Ó¸ê®Æ, ½ÐÂI¿ï¤U¦C¹Ï¥Ü.
¡@ ¡@
Leica TCS STED Leica TCS STED CW Leica TCS SP5 CARS

Integrates Super Resolution STED with the Broadband Confocal Platform TCS SP5
Leica TCS STED.

With the award-winning invention of STED technology, a new chapter in fluorescence microscopy began
¡@ The Fast Track to Superresolution !!! The new Leica TCS STED CW is the most uncomplex way to nanoscopy for research. The system resolves structures smaller than 80 nm ¡V with purely optical methods............ ¡@ Coherent anti-Stokes Raman scattering (CARS) microscopy overcomes a powerful tool for three-dimensional, label-free imaging of chemical and biological samples in vitro and in vivo.

¡@ ¡@
Leica TCS SP5 II Leica TCS SP5 X Leica TCS SP5 MP
The Only Broadband Confocal
Leica TCS SP5 II, The Leica TCS SP5 II Confocal covers a broad range of requirements in confocal and multiphoton imaging - with the full array of scan speeds at highest resolution ..........
¡@ Tune into any Excitation with Supercontinuum Confocal Leica TCS SP5 X. With the Leica TCS SP5 X Supercontinuum Confocal researchers can tune excitation wavelengths to perfectly match fluorophores, turn down laser power, and thereby increase viability for longer live cell experiments ...... ¡@ Deep Imaging at Video Rate
Leica TCS SP5 MP...........

¡@ ¡@
Leica TCS SMD FCS Leica TCS SMD FLIM Leica TCS SMD FLCS
The system acquires and analyzes FCS and FCCS (Fluorescence Cross-Correlation Spectroscopy) data. Both methods focus on quantitative analysis of transport and binding processes, in vitro as well as in vivo ¡@ It is a dedicated system for FLIM measurements. These measurements reveal information about the direct neighborhood of molecules on the nanometer scale ¡@ Fluorescence Lifetime Correlation Spectroscopy. This single molecule detection system ensures the highest flexibility in biophysics by conveniently combining FCS (Fluorescence Correlation Spectroscopy) and FLIM (Fluorescence Lifetime Imaging) in one system................

¡@ ¡@
Leica HCS A Leica TCS SPE II Leica TCS LSI
High Content Screening Automation. The combination of high-resolution true confocal point scanning technology with the ingenious LAS AF MATRIX M3 automation software for the first time offers high content screening on research microscopes. ¡@ The Leica TCS SPE confocal is a true point-scanning, spectral system at an affordable price for fluorescence imaging of live or fixed cells ........... ¡@ Capture Intra-vital Adult and Embryo Images from Macro to Micro with Leica TCS LSI. The first super zoom confocal that offers high resolution plus a large 16mm field of view for in vivo imaging

¡@ ¡@
VT infinite 3 Pinhole array Confocal Scanner ¡@ Leica Structured Illumination Microscope ¡@ Leica 4Pi

Next-generation multi-point confocal scanner. Offers low photo-bleaching with high-speed image acquisition .......

¡@

Structured Illumination solution allows image contrast improvement, image blur removal and optical sectioning in fluorescence applications

¡@ A innovative solution for Super-Resolution .......

   ¬ÛÃö¸ê®Æ ( Information )
¹p®g±½´y¦@³mµJÅã·LÃè§Þ³N·§½×»PÀ³¥Î¤¶²Ð ( CLSM Technology & Application )
Leica TCS ¥úÃЦ¡¦@³mµJÅã·LÃ誺®Ö¤ß§Þ³N¤¶²Ð ( AOTF, AOBS, Spectral Detector )
Leica TCS ¥úÃЦ¡¦@³mµJÅã·LÃ誺¹p®g¥ú·½ ( Laser system ) ¤¶²Ð
Leica TCS ¥úÃЦ¡¦@³mµJÅã·LÃ誺ª«Ãè ( Objectives ) ¤¶²Ð
Leica TCS ¥úÃЦ¡¦@³mµJÅã·LÃ誺À³¥Î³nÅé ( Application Software ) ¤¶²Ð
¨Ï¥Î©ó¦@³mµJÅã·LÃè¤Wªº¬¡²Ó­M°ö¾i³]³Æ ( Micro-incubation )
¬ü¹Å»ö¾¹ªÑ¥÷¦³­­¤½¥q Major Instruments Co., Ltd.
¥x¥_Á`¤½¥q : TEL : 02-2808-1452  FAX : 02-2808-2354  ºû­×¤¤¤ß : 02-2808-2353

°ª¶¯¿ì¨Æ³B - TEL : (07) 725-8177  FAX : (07) 725-8204

E-mail : major@major.com.tw    http://www.major.com.tw

¡@